waremax list-presets¶
List available scenario presets.
Synopsis¶
Description¶
The list-presets command displays all available predefined scenario configurations. Each preset shows its purpose, key parameters, and use case.
Options¶
This command has no options.
Examples¶
List all presets¶
Output¶
Available Scenario Presets:
======================================================================
minimal
Minimal config for unit tests (3x3 grid, 1 robot, 1 station)
Grid: inferred from stations
Robots: 1
Stations: 1
Order Rate: 10 orders/hr
Duration: 1 min (warmup: 0 min)
quick
Quick iteration testing (5x5 grid, 3 robots, 5 min)
Grid: inferred from stations
Robots: 3
Stations: 2
Order Rate: 30 orders/hr
Duration: 5 min (warmup: 1 min)
standard
Standard testing (10x10 grid, 10 robots, 30 min)
Grid: inferred from stations
Robots: 10
Stations: 4
Order Rate: 60 orders/hr
Duration: 30 min (warmup: 5 min)
baseline
Reproducible baseline (10x10, fixed seed, 60 min warmup)
Grid: inferred from stations
Robots: 10
Stations: 4
Order Rate: 60 orders/hr
Duration: 60 min (warmup: 60 min)
high_load
High load stress test (20x20, 50 robots, 300 orders/hr)
Grid: inferred from stations
Robots: 50
Stations: 10
Order Rate: 300 orders/hr
Duration: 60 min (warmup: 10 min)
peak_hours
Peak hours simulation (15x15, 20 robots, 200 orders/hr)
Grid: inferred from stations
Robots: 20
Stations: 6
Order Rate: 200 orders/hr
Duration: 120 min (warmup: 15 min)
stress_test
Maximum stress test (30x30, 100 robots, 500 orders/hr)
Grid: inferred from stations
Robots: 100
Stations: 20
Order Rate: 500 orders/hr
Duration: 120 min (warmup: 20 min)
battery_test
Battery/charging focused (15 robots, 4 chargers)
Grid: inferred from stations
Robots: 15
Stations: 4
Order Rate: 60 orders/hr
Duration: 120 min (warmup: 10 min)
Battery: enabled (400 Wh)
maintenance_test
Maintenance/reliability focused (8 hour sim)
Grid: inferred from stations
Robots: 20
Stations: 4
Order Rate: 60 orders/hr
Duration: 480 min (warmup: 30 min)
Maintenance: enabled (8.0 hr interval)
Preset Summary¶
| Preset | Robots | Order Rate | Duration | Special |
|---|---|---|---|---|
minimal |
1 | 10/hr | 1 min | Fastest |
quick |
3 | 30/hr | 5 min | Quick iteration |
standard |
10 | 60/hr | 30 min | General use |
baseline |
10 | 60/hr | 60 min | Fixed seed |
high_load |
50 | 300/hr | 60 min | Stress test |
peak_hours |
20 | 200/hr | 120 min | Peak simulation |
stress_test |
100 | 500/hr | 120 min | Maximum load |
battery_test |
15 | 60/hr | 120 min | Battery enabled |
maintenance_test |
20 | 60/hr | 480 min | Maintenance enabled |
Using Presets¶
Generate from preset¶
Override parameters¶
Choosing a Preset¶
By Development Stage¶
| Stage | Preset |
|---|---|
| Unit testing | minimal |
| Development | quick |
| Integration testing | standard |
| Release testing | baseline |
By Analysis Goal¶
| Goal | Preset |
|---|---|
| Capacity planning | high_load |
| Peak hour analysis | peak_hours |
| System limits | stress_test |
| Battery analysis | battery_test |
| Reliability analysis | maintenance_test |
See Also¶
- generate - Generate scenarios from presets
- Working with Presets - Detailed preset guide
- run - Run simulations